Voltage Monitor Module, A30-U1 DC 0-99.9V Delay Relay Controller Board for Overvoltage Undervoltage Control Voltage Detection MiOYOOW

MiOYOOW Voltage Monitor Module, A30-U1 DC 0-99.9V Delay Relay Controller Board for Overvoltage Undervoltage Control Voltage Detection

нет отзывов
Артикул: 8112396
Цвет: Нет цвета (NOCOLOR)
Размер: NOSIZE
3 170 ₽
Описание товара
Переведено автоматически
Features:A30-U1 is a DC 99.9V Voltage Monitor Module with Delay. It can flexibly set detection upper and lower limit voltage values and set triggering conditions.It can realize functions such as voltage detection, overvoltage and undervoltage control, voltage alarm switch controller etc.1>.Separated measured voltage and working voltage2>.Wide voltage monitoring range 0.1V-99.9V3>.30A high current relay control4>.Support voltage calibration5>.Real-time voltage monitoring6>.Parameter power-off saveParameters: 1>.Work voltage:DC 6V-80V2>.Measured voltage:DC 0-99.9V3>.Display voltage:DC 0-99.9V4>.Voltage calibration value:-0.5V~0.5V5>.Delay time:1~9minute or keen ON(adjustable)6>.Work current:4mA~58mA(at 24V)7>.Output type:Relay switch output(No output voltage!!!)8>.Load(Max):DC30V/30A or AC250V/30A9>.Work Temperature:-25℃~85℃10>.Work Humidity:5%~95%RH11>.Size:78*53*30mmPacking List:1PCS DC 99.9V Voltage Monitor Module with DelayApplication:1>.Industrial control equipment2>.Instrumentation test3>.Experimental data testing and monitoring4>.Solar and wind power supply system5>.Electric bicycle6>.New energy vehiclesNote:1.Please allow 1-2cm measuring deviation due to manual measurement.2.Due to the different monitor and light effect, the actual color of the item might be slight different from the color shown on the pictures. Please Understand, Thanks! About this item 1>Screen display Current Measured Voltage Value automatically after power ON. Press SET button enter into set mode and the first bit will keep flashing. The first parameter set is the Upper Limit Voltage Value. Press ENTER button to set first bit value. Its set range is 0~9 as your needs. Press SET button again to switch select the next bit and press ENTER button to change value. Press SET button at 3rd time to switch select the last bit and press ENTER button to change value. 2>Then Then First Parameter ‘Upper Limit Voltage Value’ Has Been Set. Press SET Button At 4th Time To Set Next Parameter The Lower Limit Voltage Value In The Same Methods. Note: its value needs less than the Upper Limit Voltage Value. The third parameter is to set the Voltage Verification Value. Its set range is -0.5V~0.5V. The 4th parameter is to set the Display Screen Automatically Turns OFF Remaining Time Value. 3>Its Set Range Is D-0 ~ D-9 Which Means After 1~9minute, The Screen Will Turn OFF. Note: d-0 means the screen will keen ON all the time. The 5th parameter is to set the Relay Triggering Status ‘ON H’ or ‘ON L’. ‘ON H’ : Relay output will turn ON if the Current Measured Voltage Value is more than the Upper Limit Voltage Value. Relay output will turn OFF if the Current Measured Voltage Value is less than the Lower Limit Voltage Value. It can be applied to battery discharging mode. 4>ON L’ : Relay output will turn ON if the Current Measured Voltage Value is less than the Lower Limit Voltage Value. Relay output will turn OFF if the Current Measured Voltage Value is more than the Upper Limit Voltage Value.It can be applied to battery charging mode. Automatically enter detection status after set parameters and screen stop flashing. After-Sale Service: Thanks for your purchase. If you have any problem , please feel free to contact us any time. We promise you the satisfying solutions within 24 hours. See more product details
Есть вопрос? Напишите в чат